Weld Manager
Import/Export > Weld Manager
Export weld data from the weld database. These settings define the weld report format, where the report is exported, what the report name is, and which weld data is included in the report. The settings are stored as keywords in the weldmgr.cfg weld configuration file.
Select a setting/keyword, and make your choices in the dialog that opens.
In the data field selection dialogs, click the field name under All fields on the right to include it in the export. Once selected, the field name is moved to the left, under Current field(s). You can remove a field name from Current field(s) by clicking it.
Output Format
Select one of the available export formats. This setting is used in all project locations. This setting is stored in %ncgpath%\norms\cvar\weld\weldmgr.cfg.
Output Directory
Define the location (export path) for the exported file.
When the output directory is defined here, the Export path field in Weld Manager will be locked for editing, unless the export path was manually set there previously. This setting is used for the active project location. This setting is stored in %ncgpath%\norms\lvar\weld\weldmgrlocals.cfg.
Output Filename
Define the exported file's name. This setting is used in all project locations. This setting is stored in %ncgpath%\norms\cvar\weld\weldmgr.cfg.
Excel Template
Browse for an Excel file to be used as a template for the report. This setting is only applicable if Excel is set as the Output Format. This setting is used for the active project location. This setting is stored in %ncgpath%\norms\lvar\weld\weldmgrlocals.cfg.
Weld Group
Select which weld group data fields to include in the report. This setting is used in all project locations. This setting is stored in %ncgpath%\norms\cvar\weld\weldmgr.cfg.
Welded Block
This keyword identifies the block where the block joint weld between two blocks is located. Select the fields to include for this keyword. Field values are filled in for welds between blocks only. For other types of welds, the fields are left empty. The default value is blockname. This setting is used in all project locations.
This keyword can be used in the Excel template file, and is only applicable if Excel is set as the Output Format.