Lug type 700
Lug type 700
Type macro

LABEL 1 exit |
Label 1 is always empty in lug type macros. Label 2 is not used in lug type macros. |
LABEL 3 VarStr = 'l1 700' EXIT |
Label 3 contains information for the construction database. |
LABEL 4 Quest[1] = 'Quest 1' Quest[2] = 'Quest 2' Quest[3] = 'Quest 3' Quest[4] = 'Quest 4' Quest[5] = 'Quest 5' VarStr = 'R9 31 RA 9 RB 2 RC 20 RD 100' EXIT |
Label 4 contains data for icon creation and modification in System Management. |
LABEL 5 varlug = '' IF Prof_Type[1\2] = 'hp' THEN { IF Prof_Height < 81 : varlug = 'RD 70'; EXIT IF Prof_Height < 101 : varlug = 'RD 75'; EXIT IF Prof_Height < 121 : varlug = 'RD 75'; EXIT IF Prof_Height < 141 : varlug = 'RD 85'; EXIT IF Prof_Height < 161 : varlug = 'RD 85'; EXIT IF Prof_Height < 181 : varlug = 'RD 100'; EXIT IF Prof_Height < 201 : varlug = 'RD 100'; EXIT IF Prof_Height < 221 : varlug = 'RD 100'; EXIT IF Prof_Height < 241 : varlug = 'RD 120'; EXIT IF Prof_Height < 261 : varlug = 'RD 120'; EXIT IF Prof_Height < 281 : varlug = 'RD 120'; EXIT IF Prof_Height < 301 : varlug = 'RD 135'; EXIT IF Prof_Height < 321 : varlug = 'RD 135'; EXIT IF Prof_Height < 341 : varlug = 'RD 135'; EXIT IF Prof_Height < 371 : varlug = 'RD 150'; EXIT IF Prof_Height < 401 : varlug = 'RD 150'; EXIT IF Prof_Height < 431 : varlug = 'RD 150'; EXIT } IF Prof_Type[1\2] = 'hg' | Prof_Type[1\2] = 'ho' THEN { varlug = 'R9 '<Prof_Flange>' RD 100' } IF varlug = '': varlug = 'R9 85 RD 100' EXIT |
The lug size depends on the profile type and profile height. |
LABEL 6 EnableCutout[1]='100' EnableCutout[2]='106' EnableCutout[3]='112' EXIT |
Cutout types 100, 106 and 112 can be used with this lug type. The default cutout type is 100. |
Type file

1 0 0 LET V1=-1 LET V2=4 LET V3=3 LET V4=2 LET V5 = B1+R7 LET V6 = 0 LET V7 = 0 LET V8=RD+R7/10 L RE/V2 B1 RE/V2+V6 B1+RD+V5 L RE/V2+V6 B1+RD+V5 RE/V2*V3+V6 B1+RD+V5-V7 L RE/V2*V3+V6 B1+RD+V5-V7 RE/V2*V3 B1 L RE/V2*V3 B1 RE/V2 B1 LCOLL1 RE/V2 B1 RE/V2+V6 B1+RD+V5 LCOLL1 RE/V2+V6 B1+RD+V5 RE/V2*V3+V6 B1+RD+V5 LCOLL1 RE/V2*V3+V6 B1+RD+V5 RE/V2*V3 B1 LCOLL1 RE/V2*V3 B1 RE/V2 B1 LGPR E RE/V2 B1 RE/V2*V3 B1+RD+V5 W PL 0 Lug type 700 D TY "TYPE 700" R8 "Not related to JIG: " P TH GR-A 100*TH+V8+10000 P TH AH36 100*TH+V8+20000 P TH 316LN 100*TH+V8+30000 P TH ST42 100*TH+V8+40000 P TH ALM 100*TH+V8+50000 P TH AL10 100*TH+V8+60000 |
V variables are defined by LET statements.
LCOLL lines are used for coding and Hull Viewer models.
LGPR specifies a lug-to-profile connection for a bevel.
P lines define the thickness, material type and part number. |
V variables
R variables
Profile dimension variables
|