Piping Isometrics & Spools specific attributes in dimension table
Attributes whose tag starts with 'I' are only used by Piping Isometrics & Spools.
|
Name |
Tag |
Description |
|---|---|---|
|
Auto-dimensioning style in isometric drawing |
Iad |
The purpose of this attribute is to affect dimensioning of individual parts in default annotation. Value can be:
|
|
Calculate flange rotation in isometric drawing |
.gu |
Specifies whether to calculate flange rotation in isometric drawings. For collars, stub-ends, and pressed pipe ends, setting this to 'No' indicates that rotation does not need to be calculated because the flange is a loose flange (lap joint flange). If not defined, the default value is 'Yes', and flange rotation is calculated. |
|
Color of isometric drawing symbol |
Icc |
If not set, Piping Isometrics & Spools uses the values in the Colors, Lineweight & Layer Settings. |
|
Detail symbol in isometric drawing |
Ids |
Specifies the name of the detail symbol that is inserted in automatic annotation, provided this part exists in the isometric drawing. Using the detail symbol allows showing installation details for this part. The settings for detail symbols on the isometric sheet are defined in Automatic Annotation Settings > Other labels > Part's detail symbols. This attribute can also be set in the corporate catalog, to override the value in the dimension table. |
|
Flexible curve shape in isometric drawing |
.gy |
Specifies how to draw a flexible curve. This attribute can also be set in the corporate catalog, to override the value in the dimension table. |
|
Line width index of isometric drawing symbol |
Icp |
If not set, Piping Isometrics & Spools uses the values in the Colors, Lineweight & Layer Settings. |
|
No partnumbering in isometric drawing |
Inp |
A part that has this attribute does not get a part number. This attribute can also be set in the corporate catalog, to override the value in the dimension table. |
|
Special 3D iso symbol definition |
I3D |
Specifies a tag record that draws a special symbol. This can be used when conventional 2D isometric symbols are not suitable for the component in question. Also, this is the only way to define the isometric symbol when the geometry type of the component is DM_GT_FLEXCOMP. These components are not dimensioned in isometric drawings. For more information, see Special 3D iso symbol definition. This attribute can also be set in the corporate catalog, to override the value in the dimension table. |
Piping Isometrics & Spools specific attributes in corporate catalog