Insert terminal blocks and connectors
Let's insert terminal blocks for the control system +CS1 and the distribution board +MCC1. Let's also insert device connectors for B1.
Do the following:
-
In the Symbols window, select Terminals and insert the terminal block symbol. The Insert terminal block / connector dialog opens.
-
Define the following for the control system +CS1:
-
ID – X1
-
Number – 1
-
Number of symbols and insertion mode – Space evenly, 16
-
-
Indicate the insertion point for the first terminal block (= location).
-
Indicate the connector number inside the location boundaries, and click.
-
Indicate the insertion point for the second terminal block (space between terminal blocks 6 raster points = 6 x 3.5 mm.
-
Move the terminal blocks (5–16) according to the example drawing:
-
Select the terminal blocks to be moved (5-16) in the selection dialog.
Note: Select the terminal blocks from bottom to the top.
-
Right-click and select Move.
-
Indicate the new location.
-
-
Insert the rest of the control system +CS1 terminal blocks as described.
-
Insert the distribution board +MCC1 terminal blocks X11:10–14 and 17–18 as described.
-
Define the following:
-
ID – X11
-
Number – 10
-
Number of symbols and insertion mode – One by one, 5
-
-
Insert terminal blocks 17 and 18.
Tip: Align the X11 terminal blocks with the +CS1 terminal blocks.
-
- Insert B1 device connectors - and +: first number -/+.
![]() |