Isometric Check Results

Plant Modeller automatically checks whether the piping parts in an isometric group are continuous (connected to each other) and whether they are connected to parts outside the isometric group. In addition, the project administrator can select various other checks, such as collision checks and bending checks, to be run at the same time. In the Isometric Groups pane, the list of isometric groups shows a red exclamation mark next to those groups that have failed their checks and an orange exclamation mark where the results are outdated due to other changes in the project. The results of failed checks can be investigated in detail and then the problems can be either corrected or marked as ignored.

Note: Preliminary checks can be run already before the isometric groups are created. See Create New Isometric Group.

Prerequisites

  • Project administrator has defined which Isometric Checks are to be run in the active isometric group type.

Do the following:

  1. On the Piping Isometric tab, in the Isometric Groups pane, hold down Ctrl or Shift and select the isometric groups whose check results you want to see.

  2. Right-click the selected groups and select Show check results from the Isometric Groups context menu. The program runs the specified tests if needed and then the Isometric Check Results dialog opens, listing the included isometric groups in this order:

    Successful – Isometric group has either passed all the checks or the failed checks have been marked as ignored.

    Not up to date – Isometric group has outdated check results and the checks are to be re-run.

    Failed – Isometric group has failed some or all of the checks.

  3. If the dialog lists isometric groups that have failed checks, investigate the problems and see if they can be fixed.

  4. If the Collision column of some isometric groups displays the text "Recheck required", select those isometric groups and click Check Again to have them re-checked.

  5. If there are problems that you cannot or do not need to fix at the moment, you can set the check results to be ignored.

  6. You can export the check results to a Microsoft Excel (*.xlsx) file.

  7. Click Close.