Release notes

CADMATIC Electrical has three main releases annually. The release name identifies the publishing year, tertial (T1–T3), and possible patch update designation (R2 or higher). These release notes describe new features, improvements, and bug fixes made in software version 2024T1.

Release notes for CADMATIC Draw are available here.

Old CADMATIC Electrical release notes:

New features and improvements in 2024T1

Renewed user interface

In this release of CADMATIC Electrical, we are introducing a completely new user interface based on the ribbon. Within the ribbon, the functions familiar from the toolbars are now located in logical tabs and groups. The most essential functions are easily available, and the buttons also have the function name clearly shown. Furthermore, the buttons include a tooltip with a link to the instructions.

In addition to the new ribbon, the command line has been improved. It now takes up less space, leaving more room for the drawing area.

For more information, see the following topics:

Other new features and improvements

Previously, we used the term "application" for the Electrical sub-applications Schematics, Layout, Distribution Board, and Cabinet Layout. We have now merged all the functions into a single Electrical application. Furthermore, we have organized the functions into toolsets based on the types of documents they are intended to create – in the ribbon, these toolsets are on their own tabs.

This software release contains the following new features and improvements.

Toolset

Category

Description

All

Terminology

The following term changes have been applied:

  • In Schematics, the term cable combing has been replaced with cable termination.

  • In Layout, the term fluorescent light has been replaced with linear light.

  • In Layout, the term raceway has been replaced with cableway.

  • In Layout, the term package symbol has been replaced with symbol group.

  • In Cabinet Layout, the term race-way has been replaced with duct.

  • In the project tree:

    • Distribution boards and groups has been replaced with Distribution boards and feeders.

    • Floors and spaces has been replaced with Storeys and spaces.

  • In DB Tool, the Reports function now consistently talks about reports instead of lists, for example:

    • List options is now Report options.

    • Create lists is now Create reports.

    • Create separate lists from groups is now Create separate reports from groups.

  • In DB Tool, terms related to space functions have been changed as follows:

    • Space number > Space ID

    • Number text > Space number

    • FlatApartment

All

Project settings

Two new date formats, dd-mm-yyyy and d/m/yyyy, have been added to the Date format (default) menu options in the Common section.

All

Project settings

In the Common, symbols section, the new Mark 'To be deleted' cables into the drawing option allows the user to select whether to show the cables marked as to be deleted in the drawing.

All

Project tree

In the Documents project tree, it is now possible to close drawings via the project tree by right-clicking and selecting Close drawing.

  • If you select to close the current document, the application and the drawing are changed.

  • If you select to close a drawing other than the current one, the application will not be changed.

All

Documents

Some of the drawing types have been renamed to better indicate the significance of the drawing type versus application; the drawing type designates what can be done with that application. The main changes are the following:

  • There is a new toolset called Single-line that covers the single-line functions that were previously in the Schematics application. In addition, the Distribution Board application has been incorporated into Single-line as its own toolset.

  • The document type associated with the Schematics application has been renamed to Multi-line. You can create all types of multi-line documents, such as connection diagrams, termination diagrams, and schematic style diagrams, with it.

Due to the changes mentioned above, the Start a new Electrical drawing dialog has been renewed:

  • You can open the function by selecting Electrical tab > Documents group > New.

  • The different drawing types are now grouped based on the application.

  • The new Single-line application drawing types, Single-line diagram and Load diagram, are grouped under Single-line. Furthermore, the former Distribution Board Schema drawing type has been renamed as Distribution board (table), and it is also located under Single-line.

  • The Layout application drawing types have been renamed: the former Layout drawing type is now Arrangement, and the former Layout, Schema drawing type is now Arrangement (not in scale).

  • The former Schematics application drawing type Schema has been renamed as Multi-line diagram.

For more information, see Create new drawings and Drawing types.

All

Revisions

You can now draw a revision cloud. The Cloud function is available on the Electrical tab, in the Revisions group.

All

Symbols

In the Symbols window, there is a new tab with the icon. On this tab, you can select another drawing type whose symbols you want to show in the dialog temporarily. In an arrangement drawing, for example, you can select to show symbols from the Schematics application drawing type.

This setting will be valid for as long as you have the Symbols window open. Once you close the window and open it again, symbols will again be shown based on the current drawing type.

For more information on the Symbols window for each toolset, see the following:

All

Symbols

The following symbol editing functions are now available in the Symbols window:

  • Delete symbol

  • Move symbol

  • Move symbol and stretch wiring (not in Cabinet Layout)

  • Copy symbol

  • Edit symbol

  • Change symbol (not in Cabinet Layout)

For more information on the Symbols window for each toolset, see the following:

All

Tables

The creation of a drawing list has been improved:

  • If there already are elements on the sheet when you start the function, the program asks if you want to create a new sheet. If you select to create the new sheet, the list is added there.

  • If the list continues to another sheet with elements on it, a new sheet is now created to fit the list.

All

Attributes

You can now sort the rows in the Edit values for copied objects dialog based on the desired information by clicking the column header.

Single-line

Toolsets

A completely new toolset called Single-line has been added.

  • With Single-line, users can create various documents: single-line documents, load diagrams, and distribution diagrams.

  • All the single-line functions that were previously included in Schematics are now in Single-line. Some new features, such as a new symbol library, have also been added.

  • The toolset includes the functions of the former Distribution Board application, as the distribution board document serves as a variant of a single-line document. For more information on the Distribution Board functions, see Distribution Board (Table).

  • Customers who previously had the Schematics application will now automatically receive the new Single-line toolset and have access to all its functions.

Single-line

Distribution boards

Updating symbol packages after symbols have been removed has been improved.

Layout

Symbols

The Insert symbol on operating sector function now allows users to create four types of sectors:

  • Traditional sectors (angle of 1–359)

  • Full circle sector

  • Full circle sector with polygon inside it

  • Free form sector

Layout

Wiring

With the Wire marking (automatic) function, the cable ID is now marked to the ID attribute of the marking symbol. By default, the attribute is hidden but can be shown by turning on ID attributes for symbols.

Layout

Cableways (former Raceways)

You can now edit both cableways and vertical cableways with the same Edit function that is located to the Cableways group on the Layout tab. The function opens the right editing function after you have selected the cableways to be edited.

Layout

Boundaries

You can draw location boundaries to arrangement drawings with the following functions:

  • Single-line tab > Cabinets and feeders group > Boundary

  • Schematics tab > Other functions group > Boundaries menu > Location boundary

  • Cabinet Layout tab > Cabinets group > Draw menu > Location boundary

Layout

3D

The visualization window has been renewed: The round tool menu has been replaced with a new toolbar. In addition, a viewcube tool is available for changing the view direction.

Layout

Spaces

Space information can now be read from the space objects in reference drawings.

Layout, Schematics

Integration

Information about deleted cables is now included in export. This way, it is possible to only update the cables in Plant Modeller, instead of synchronizing all changes.

Schematics

Attributes

There are two new functions in the auxiliary functions menu:

  • Hide attribute from all symbol's occurrences – With this function, it is possible to select a symbol and hide the attribute from all the symbol's occurrences.

  • Show attribute from all symbol's occurrences – With this function, it is possible to select a symbol and show the attribute for all the symbol's occurrences.

Schematics

Wiring

With the new Show text option in cable termination pair shield settings, you can select to either show or hide the pair shield text.

Schematics

Wiring

Removing cable terminations and cable termination occurrences has been improved: Removing the determining element also removes the connections. If the other end of the cable termination has been connected and the other not, the reference is not removed from the unconnected end.

Electrical DB

Usability

The performance of the application has been improved.

Electrical DB

Usability

Drop-down menus where filtering is possible (in the grid, for example) have been improved to be case-insensitive, i.e. you now get the same search results when typing uppercase and lowercase letters.

Electrical DB

Management

A new function, Type definitions, has been added to the Management tab. This function allows the user to add their own device types into the database, and then define them to the devices on the Devices tab or in the Device properties dialog.

Electrical DB

Management

In cable type, cable package definition, product information, additional information, plate definition and product model management dialogs, you can now update the latest changes made by other users to be shown in the grid with the button.

Electrical DB

Grids

It is now possible to collapse and expand all grouped data rows by right-clicking in the grid or auxiliary grid and selecting Collapse all rows and Expand all rows.

Electrical DB

Terminal blocks

On the Terminal blocks tab, in the Incoming wires and Outgoing wires columns, the values are now represented as follows: [cable ID or wire type] : [wire number] [wire color] ([from/to device full ID:pin]).

Electrical DB

Documents

It is now possible to change the document name from the label rows with the Rename option.

Electrical DB

Documents

If a project document is not found in the project directory but it is in the project database, it is marked with red on the Documents tab. In the project tree on the drawing side, the document is marked with gray.

Electrical DB

Groups

You can now select several feeders for which you want to create the same protective device. If you select feeders that already have a protective device, they are edited according to your definitions.

Electrical DB

Groups

The Schematics column has been added, and it can be selected to be shown in the grid with the Show columns function.

Electrical DB

Customer IDs

It is now possible to generate the desired kind of dynamic customer ID also for cable packages.

Bug fixes in 2024T1

This software release contains the following bug fixes.

Toolset

Category

Description

All

Labels

When inserting label symbols, the coordinates were not always taken into account when the symbol had a language ID.

All

Settings

The symbol standard and location settings were not correctly saved if the drawing was not in a project.

All

Tables

When creating drawing lists, the rows did not always fit on the sheets, resulting in overlapping rows.

Single-line

Distribution boards

Importing and exporting group data did not work as should.

Layout

Distribution boards and groups

The Properties window did not always show the length value.

Layout

Wiring

The wiring marking settings defined in the Wiring dialog were not applied when drawing.

Layout

Wiring

Starting to edit wiring information from the drawing sometimes crashed the application.

Layout

Wiring

Cable package marking was not shown correctly if there was an overlapping wiring onto the marking was added.

Layout

Wiring

Neutral conductor and protective earth were drawn even though PEN was selected.

Layout

Wiring

The Connect symbols to wiring  function broke wiring marks and added them incorrectly.

Layout

3D

In 3D part generation, selecting cables and tubes to be generated crashed the application.

Layout

3D

In IFC export, editing one piece of product information affected multiple pieces of product information.

Layout

3D

All cableway types were exported to IFC even when they had not been selected.

Layout

Cableways (prev. Raceways)

Sometimes making a gap to a cableway crashed the application.

Layout

Cableways (prev. Raceways)

Removing raceways from a drawing did not work correctly.

Layout

Devices

When changing device size according to an occurrence, the Z size was not taken into account for 3D symbols.

Layout

Symbols

If user saved their own symbol with special characters in the name, the symbol was saved but not available in symbol menus.

Layout

Symbols

Symbols did not always work correctly when the product model had an address as additional information.

Layout

Symbols

The application was slow with a large number of symbols.

Layout

List functions

When counting light fixture positions, the 3D elements were included.

Schematics

Wiring

The wire ID was not changed when wiring through a symbol.

Schematics

Wiring

Deleting a wire in wire properties and then editing it via the project tree resulted in an error.

Schematics

Wiring

When adding a reference with the Draw this wire function, the wire data of the wire being drawn disappeared.

Schematics

Wiring

In wiring and cable combing, starting cable type management resulted in the application crashing when the drawing was not in a project.

Schematics

Wiring

The application sometimes crashed when drawing cable termination (prev. cable combing).

Schematics

CAD reports

Unnecessary rows were sometimes created in CAD reports.

Schematics

Single-line

It was not possible to insert a feeder symbol via the Distribution boards and groups project tree when the symbol was assigned to the feeder.

Schematics

Terminal blocks

When a terminal block was inserted on wiring, the wiring was not cut below the symbol.

Schematics

I/O

The station ID was not updated to the drawing if the ID had been created via the I/O card property dialog.

Schematics

References

References to contactors representing multiple parts were not shown correctly in PDFs.

Schematics

Boundaries

Adding additional information for a location boundary resulted in the application crashing.

Schematics

Boundaries

Circuit generation did not work with device boundaries.

Schematics

Attributes

The length of the common attribute value was not checked which resulted in an error when opening a drawing.

Schematics

Product models

When the product model was removed from an I/O card the channels were also removed even though that had not been selected.

Layout, Schematics

Integration

User-defined system information was not shown when mapping systems.

Layout, Single-line

Distribution boards and groups

In Distribution board and group management, zeroes were removed from the beginning of group numbers in connection with copying.

Layout, Single-line

Distribution boards and groups

In Distribution board and group management, the Move to another distribution board function allowed inserting another distribution board's group to a different distribution board's drawing.

Layout, Single-line

Distribution boards and groups

When the drawing was not in a project, checking the group numbers did not work correctly. Therefore, when adding a group that was already in the drawing no notification was given.

Layout, Single-line

Distribution boards and groups

In Distribution board and group management, column headers were incorrect if Electrotechnical calculations was not selected.

Cabinet Layout

Terminal blocks

The Terminal strip to drawing function did not use the symbol defined in product information.

Cabinet Layout

Frames and sheets

The Set sheet function did not change the scale for the drawing frame.

Cabinet Layout

3D

With product model devices, the wrong 3D symbol was used.

Electrical DB

Structure

It was possible to save changes even when the database structure was not up-to-date.

Electrical DB

Settings

When using picking lists, the description was taken to the database instead of the value.

Electrical DB

Properties

Wiring properties and circuit properties were not always saved correctly.

Electrical DB

Properties

Locking of planning area and device type information worked differently in the grid and the Device properties dialog.

Electrical DB

Management

Project clean-up also cleaned objects not selected to be cleaned.

Electrical DB

Devices

When the product model was changed in device properties, the product model information was not updated in the drawing.

Electrical DB

Product models

Updating or replacing a product model sometimes resulted in an error.

Electrical DB Product information When adding the same product information, the previous definitions were removed instead of increasing the quantity.
Electrical DB

 

Product information

 

When replacing product information, a new piece of information was created when the selection included information that did not exist yet.

 

Electrical DB

Product information

Product information was not copied from a cable along with the cable.

Electrical DB

Additional information

If there were two pieces of additional information with the same attribute, they were not updated correctly.

Electrical DB

Documents

Removing a document from the project sometimes resulted in an error.

Electrical DB

Reports

If there were special characters in the target directory, the application crashed.

Electrical DB

Reports

Creating a report resulted in an error if another document was open in Excel at the same time.

Electrical DB

Reports

If the absolute path led to the project folder or its sub-folder, reports from the project copies were also stored to the original project.

Electrical DB

Modular generation

Removing already generated material in Windows Explorer and then starting generation for the same material again resulted in an error.

Electrical DB

Modular generation

When several cells were selected for the Assign to template drawing function, only the first value was applied.

Bug fixes in 2024T1R2

This software release contains the following bug fixes.

Toolset

Category

Description

Single-line

Drawing frames

It was not possible to set a default drawing frame for drawings of the single-line type.

Single-line

Distribution boards

When the location was changed for a distribution board frame, duplicates were created of all feeders.

Single-line

Wiring

Wiring references did not work as should in single-line diagrams and load diagrams.

Single-line

Wiring

When drawing a cable package, it was possible to select an existing one but it was assigned a new ID.

Single-line, Schematics

Wiring

It was possible to create cables without systems.

Schematics

Wiring

When several wires were created for internal wires, wire harnesses and busbars because of cut points, they were all given the same ID instead of a running ID.

Schematics

Wiring

The Redraw wire function did not use the original wire color.

Schematics

Wiring

Changing the cable package definition in the Cable package properties dialog resulted in an error.

Schematics

Devices

Pin values or signal types were not shown in the Insert object info to drawing dialog.

Schematics

Symbols

When inserting a device occurrence via the project tree, the Other symbol button in the insertion dialog did not show user symbols.

Schematics

References

When drawing wiring with a reference, two references were created.

Layout

Wiring

When a cable type was added and a cable of that type was drawn to a drawing not in a project, cable wires were shown only after saving, closing and reopening the drawing.

Layout

Raceways

Copying raceways did not work as should.

Layout

3D

Generating collision geometry for reference drawings did not work as should.

Cabinet Layout

Devices

When inserting a device via the Cabinet Layout tab, F8 did not work for rotating the symbol.

Electrical DB

Project tree

DB Tool crashed when a lot of items were selected in the project tree.

Electrical DB

Devices

On the Devices tab, the Circuits auxiliary grid did not show circuit type or circuit number. Furthermore, the customer circuit name field did not show the dynamic circuit even if it existed.

Electrical DB

Devices

When removing a product model from a device, the pins were also removed even when they had occurrences.

Electrical DB

Distribution boards

Creating a distribution board in an SQL project sometimes resulted in an error.

Electrical DB

Product models

When setting additional information for product models, the value was handled incorrectly.

Electrical DB

Reports

It was not possible to select settings located outside the project directory from the Saved report settings drop-down menu.

Electrical DB

Import

It was not possible to remove an imported clipboard project which then prevented new imports.

Electrical DB

Import

When importing I/O card information, errors were not included in the corresponding Excel file.

Bug fixes in 2024T1R3

This software release contains the following bug fix.

Toolset

Category

Description

Electrical DB

SQL

In SQL project management, updating the view did not work.